192-011003N7_PSD1-M_Short_Description
192-011003N7 DOC-0001-01-B 11.12.23 11:39 27 (31)
7.2 Mains connection Power module PSD1-M_P010 with line choke
Increased power by means of a line choke
PSD1-M_P010 with line
choke
device
Measure for line and device protection:
UL listing (DIVQ) automatic circuit breaker
Manufacturer: ABB, Stotz-Kontakt GmbH (E212323)
Model No.: S203UP-K, 1 automatic circuit breaker
480 VAC, 3-phase, 25 A, Operating temperature 55 °C
Current on the mains PE (>3,5 mA)
Possible supply networks: TN
The specified performance data are only valid in connection with line choke
IND-0001-02.
7.3 Mains Connection Power module PSD1-M_P020 without line
choke
device
2 fuses in line are required
Measure for line protection:
MCB (K characteristic) with a rating of 50A / 4xxVAC (depending on the input
voltage)Recommendation:
Recommendation: (ABB) S203U-K50 (440VAC)
Measure for device protection:
Fuses 80A / 700VAC per supply leg in accordance with UL category JFHR2:
Essential: Bussmann 170M1366 or 170M1566D