Figure 11: High-side output installation connections
4.2. 3 A High-Side/Low-Side Outputs
The VMM1210 has 2 programmable high or low-side outputs capable of 3 A:
OUTPUT9_3A to OUTPUT10_3A
The outputs can be programmed through the VMM software package to be:
High-side
Low-side
H-bridge
4.2.1. High-Side/Low-Side Output Capabilities
Each output is rated at a continuous current of 3 A. These outputs along with the
other 8 outputs must have a total current of no more than 80 A per module.