TS ID To set the TS ID.
Program List To select which services will be output by Remux.
CI Source To configure the CI descramble source, user can select
Tuner Input, ASI-1 Input, ASI-2 Input, IP Input or Remux
Input.
CI Setup To set which programs should be descrambled by CI slot1
or CI slot2.
CI
CI CAM Name To check what kind of CAMs have been inserted.
BISS Mode To select the BISS mode, user can choose between Off,
BISS-1 and BISS-E.
BISS Source To select the BISS source, user can select Tuner Input,
ASI-1 Input, ASI-2 Input or IP Input.
BISS
Program To select which services will be decrypted by BISS.
Emb Aud Switch To enable or disable the embedded audio
Emb Aud Mapping To select which audio to be embedded in which group
SDI
Closed Caption Mode To configure the Closed Caption mode over SDI, user can
select between Auto, Line21, SMPTE 334-608 and
SMPTE 334M-708.
Switch To enable or disable the Redundancy function
Main Port To configure the main output source, user can select
Tuner Input, ASI-1 Input, ASI-2 Input or IP Input.
Backup Port To configure the backup output source, user can select
Tuner Input, ASI-1 Input, ASI-2 Input or IP Input. The
backup port can not select the same source as main port.
Main CH Unlock Time To define the condition of the backup port.
Main CH Recover Time To define the condition when the main port recover.
Redundancy
Backup Mode To configure the decoder output mode, user can select
between Auto and User Define Program.
5.1.5 System menu
In this menu, you can check and set system settings and read the equipment information, and make the default
factory setting and so on. There are nine submenus, including Version Info, IP Control, Product Name, Model,
Factory Settings, Machine Type, LCD Language, Safety Level, and Upgrade. Use UP or DOWN key to scroll the
submenu, and press ENTER to go into each submenu.
Version Info