25ENGLISH |
n
Unscrew and remove the lling plug and the vent plug.
o
Pour in about 1.5 litres of water until it pours out of the
vent hole.
p
Rescrew the lling plug and the vent plug.
q
Open the water tap
r
Attach the plug to the electricity supply.
s
Turn the switch to “I”.
t
SIMULTANEOUSLY press buttons and for 5 seconds.
DG PED enters into a priming mode.
GREEN LEDS
FLASHING
RED LED
FIXED
u
Press button to start priming.
GREEN LEDS
FLASHING
GREEN LED
FLASHING
The priming procedure lasts at most 5 minutes, at the end of each minute DG PED automatically stops the electric pump
for ve seconds then immediately restarts it. This is repeated for all the time the DG PED is priming. During this procedure
the LEDS will continue to ash.
The exit from the priming procedure can occur either because of time out (5 minutes) or because it is completed. The
LEDS stop ashing. If the pump does not prime repeat the operation from the start.