Installer Manual Fleck 3900 - NXT - Description
Ref. MKT-IM-015 / B - 08.06.2018 15 / 126
Electrical
Controller operating voltage .................. 24 VAC
Input supply frequency ........................... 50/60 Hz
Transformer voltage............................... 24 VAC
Motor input voltage................................. 24 VAC
Power consumption ............................... 105 W
Controller protection rating ................... IP 22
Valve protection rating ........................... IP 44
Power supply .......................................... 230 VAC, 50/60 Hz, 105 VA, Class II
Transient over-voltages ......................... within the limits of category II
Pollution Degree..................................... 3
Temporary over-voltages must be limited in duration and in frequency.
Model without transformer
Warning
A switch or circuit-breaker must be included in the installation, it must be suitably located
and easily reached, it must be marked as the disconnecting device for the equipment.
Warning
The power must be achieved by a transformer in which the primary windings are separated
from the secondary windings by REINFORCED INSULATION, DOUBLE INSULATION, or a
screen connected to the PROTECTIVE CONDUCTOR TERMINAL.
Warning
It is required the installation of a fuse as over-current protection, it has to be positioned
between the system and the secondary of the transformer in the installation with the
following characteristics: V>= 30Vac, Imax=10A (ES. 10x20 10A)
Environmental conditions
• Indoor use only;
• temperature from 5°C to 40°C;
• maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative
humidity at 40°C;
• mains supply voltage fluctuations up to ±10% of the nominal voltage.