EasyManua.ls Logo

Pentair FLECK 3900 NXT - Valve on Tank Assembly

Pentair FLECK 3900 NXT
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 3900 - NXT - Maintenance
94 / 126 Ref. MKT-IM-015 / B - 08.06.2018
9.2.10. Valve on tank assembly
No. Operation
A Lubricate the seals with approved silicone grease.
B Spin the valve (1) onto the tank (2), ensuring the threads are not cross-threaded.
C Rotate the valve (1) clockwise and freely, without using force until it comes to a stop.
Note
This stop position is considered point zero.
D Rotate the valve (1) clockwise from point zero to between ¼ turn and ½ turn.
Caution
Do NOT exceed 27 Nm of torque when installing the valve. Exceeding this limit may damage
the threads and cause failure.
½ turn
¼ turn
Point 0Point 0

Table of Contents

Related product manuals