EasyManua.ls Logo

Pentair FLECK 3900 NXT - Remote Started Regeneration; Display Format

Pentair FLECK 3900 NXT
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 3900 - NXT - Programming
Ref. MKT-IM-015 / B - 08.06.2018 67 / 126
Options:
•down flow;
up flow (not for 2850 valve type);
up flow fill first (only for 2750 and 2900/2910 types).
6.5.10. Remote started regeneration
Start regeneration from an external signal (see chapter 5.9. Electrical connections, page 52).
Note
The contact will close after a preset duration. When the contact closes, the regeneration
starts.
Note
This mode can be combined with the other methods of regeneration; it has priority once it is
activated.
6.5.11. Display format
Set the unit system to be used.
Options:
US GALLONS: volume in gallons, time display 2 x 12 hours, hardness in grains;
EU-METRIC-LITERS: volume in litre, time display 24 hours and hardness depends on the
language:
EN: mg/L as CaCO
3
FR: °F GE: °dH IT: °TH SP: °TH
N Set regeneration flow with and .
→ Default setting: down flow
O Press to validate the selection and advance to the next
parameter.
REGENERANT FLOW:
DOWN FLOW
P Set the remote controller with , and .
→ Can be adjusted from OFF to 01:39:00.
Q Press to validate the selection and advance to the next
parameter.
Without remote controller.
REMOTE SIGNAL
START:OFF
With remote controller and 1
minute contact programmed.
REMOTE SIGNAL
START: 00:01:00
R Set the display format with and .
S Press to validate the selection and advance to the next
parameter.
DISPLAY FORMAT:
EU-METRIC-LITERS

Table of Contents

Related product manuals