5. After pressing , the Home screen (Figure 8) appears.
Figure 8 Home Screen
The Day and Time button will be flashing, indicating that the
day of the week and time need to be set. If the date and time
are incorrect, press the Day and Time button to update to
the correct day and time. The Day and Time screen (Figure
9) appears.
Figure 9 Day and Time Screen
Press the Day of Week, Hour, Minute, and AM/PM/HR
buttons to adjust the values to the correct day of week
and time. Setting the value of the AM/PM/HR button to
HR changes the display to a 24 hour clock. Press the Day,
Month, and Year buttons to adjust the values to the correct
date. Press the
button when finished to return to the
Home screen. Press
to return to the Home screen
without saving.
Day and Time
Regeneration
Settings
Regeneration
Cycle Wheel
Next Scheduled
Regeneration
Current Cycle
Step
Diagnostics
Assistance
Month
Day
Day of Week
Minute
Hour
AM/PM/HR
Year
6. Start a regeneration by pressing the Regeneration button
. The Regeneration screen appears (Figure 10).
Figure 10 Regeneration Screen
Press now to begin a regeneration immediately, or
press at regen. time to queue the regeneration for the
programmed regeneration time (2:00 AM default for
softeners, 12:00 AM default for filters). Pressing at regen.
time again will cancel the manual regeneration.
During Regeneration, press the
button to immediately
advance to the next cycle step. Once in regeneration, the
volume or time will be displayed below the
button.
7. For softener systems, put salt in the brine tank.
NOTE: Do not use granulated or rock salt.
The unit is now fully programmed and ready to treat water.
This quick setup uses the control's default settings, which are
appropriate for most residential applications.