Setting Priming Time Press to access Max Priming Time.
Press and to select digit to modify. Change values by pressing and .
When value is set, press to confirm value and save changes.
Note: The “System Priming Time” menu should only be used when excessive
amounts of air need to be evacuated from the system. The IntelliFlo
®
VF Variable
Flow Pump can prime in seconds, but additional time may be needed to fill other
devices – e.g., filters or solar heating systems.
Filter Settings Press to scroll to Filter menu.
The pump is constantly monitoring filter pressure, and when it detects that the
system needs cleaning, an “Alert – Service System Soon” message will appear on
the control panel display. This parameter can be set from 1 PSI to 50 PSI, and
establishes when the “Service System Soon” alert will activate. Average setting
should be between 10 PSI and 20 PSI for most pools and filters. Note: PSI
changes can come from anywhere in the system, e.g., clogged skimmers or pump
strainer baskets. Note: Initial start-up and installation of the IntelliFlo pump must
always be performed with a clean filter. If the filter has been in use, run the filter
backwash cycle before start-up.
Press to access Clean Filter Pressure setting.
Press and to select digit to modify. Change values by pressing and
When value is set, press to confirm value and save changes.
Enter
Enter
Clean Filter Pressure
Setting
IntelliFlo
®
VF Pump Quick-Start Guide
10