Setting Priming Time – Filter: Turnovers/Cycles
Turnovers Per Day Press to scroll to Turnovers.
This setting establishes number of times the entire volume of water will turn over per day.
One turn per day is recommended for energy conservation and for most common pool
requirements. This setting can also be modified to easily increase system flow if required
for more effective skimming. You can set up to eight turns per day.
Press to access Turnovers Per Day.
Press and to select digit to modify. Change values by pressing and
When value is set, press to confirm value and save changes.
Cycles Per Day Press to scroll to Cycles.
IntelliFlo
®
VF Variable Flow Pump uses the Cycles Per Day setting to calculate
how much time it has to complete turnovers/filtration. You can program up to four
start/stop cycles per day.
Press to access Cycle value.
Press and to select digit to modify. Change values by pressing and
When value is set, press to confirm value and save changes.
Enter
Enter