Posi-Chlor® Salt Water Chlorinator Owner’s Manual Posi-Chlor® Salt Water Chlorinator Owner’s Manual
25
4. START-UP AND ADJUSTMENTS
NOTE: if working in automatic, you can also adjust the production percentage from 0% to
100%,
On connecting the equipment in automatic mode, the ORP value will flash for 5 min before
the equipment starts to produce chlorine.
4.4.3 Super chlorination
Select this option if you require super-chlorination of your swimming pool, bearing in mind
the following:
• If the equipment is working in semi-automatic mode (with the Temperature Probe
Kit), the equipment will calculate the time necessary depending on the volume and
Temperature. The filtering time to perform super-chlorination will be displayed on the
screen.
• Without a Temperature probe, super-chlorination will be carried out for 24 hours. If
filtration is stopped, super-chlorination is suspended.
4.5 pH Menu (Advanced)
With this menu, you can adjust the parameters related to the pH adjustment of your
swimming pool. It only appears in advanced pH/ORP model units. The reading of the pH
probe can be seen in the 3rd line of the main screen. You can access the pH menu from the
main menu by pressing OK.
4.5.1 pH Adjustment
Go to the main menu, select "pH" and in the pH menu that is displayed, select “pH +-”
Use the buttons to adjust the required pH and conrm with "OK".
4.5.2 Calibration of the pH probe
To calibrate the probe, prepare a glass with clean water. Remove the probe from the stor-
age liquid, shake off the liquid and stir it in the water. Shake it again to remove the water.
Dry with a clean cloth, without rubbing.
In the control, go to “Menu” – “pH” – Calibration. The 1st line of the display indicates "pH cal. =
7” . Submerge the probe in the pH7 solution and press OK.