Posi-Chlor® Salt Water Chlorinator Owners Manual
18
4. START-UP AND ADJUSTMENTS
4.2 Main Menu
The following table shows how to organise the configuration menu of the equipment:
Main Menu Sub Menu Default Notes
Conguration
Language English Use to change display
language.
Control Manual (Basic & pH).
Auto (Adv. pH/ORP).
Cleaning 6 Hours Use to select cleaning
cycle (reversing) time.
Volume 20m3 Use to select pool
volume.
Outdoor / Indoor Outdoor Use to select pool
location.
Cover N Use to select option pool
cover input switch.
Flow Switch N Use to select optional
ow switch.
Acid Alkali This option cannot be
changed.
pH Alarm Y Use to select optional pH
alarm.
Chloride Alarm N Alarm detects if there is
no change in ORP after 2
hours of SCG operation.
Buzzer N Turns on audible buzzer
with associated alarms.
Chlorination
% of production 50% Select chlorine output of
cell 0-100%.
Max ORP / Cl 700 ORP set point value.
Super chlorination Off Super-chlorination
function.
pH
pH +/- 7.3 pH set point value.
Probe Calibration For probe calibration on
initial start-up.
Manual Pump Priming Press to manually run pH
dosing pump