9.2.5. Cleaning the injector and the injector screen
No. Operation
A Using a screwdriver, unscrew the screw (2).
B Remove the controller (1) from the valve (9).
C Manually actuate the pistons (8) to drain the water from inside the valve.
D Using a screwdriver, unscrew the three screws (3).
Caution
Unscrew the screws slowly to prevent gripping between the material and the screws.
E Remove the collector (4).
F Remove and clean the injector (6) and the flow breaker (7).
G Using pliers, remove and clean the injector screen (5).
Note
Use water or compressed air to clean the injector, flow breaker and injector screen.
H Replace and grease all the O-rings with silicone grease (cod. 8500).
I Reverse above procedure steps to rebuild.
Caution
When reassembling the collector :
- Try to match the self tapping screws with the original thread;
- Slowly screw by hand without forcing then tighten using a screwdriver;
- Always carry out these operations using normal screwdrivers; do not use automatic
screwdrivers.