9.2.6. Replacing the drain connection
No. Operation
A Unplug the pilots to drain tube (3).
B Push out the two locking pins (1).
C Slip off and change the drain manifold (2).
D Replace and grease all the O-rings with silicone grease (cod. 8500).
E Reverse above procedure steps to rebuild.