Installer manual Siata V132 - SFE - Troubleshooting
76 / 88 Ref. MKT-IM-003 / B - 19.04.2017
No brine draw.
Low water pressure at the inlet.
Close the outlet of the valve, check that
the pressure gauge shows a pressure
of at least 2 bars. If it is lower, the
pressure is insufficient. If the pressure
is higher than 2 bar, check the
mechanical filter which is installed
before the injector is plugged by dirt.
Remove it and clean.
Screen on the manifold is plugged by
dirt.
Remove manifold and screen and
clean thoroughly.
Plugged injector.
Remove injector, thoroughly clean the
holes in the injector and remount it.
Problems in salt / brine tank.
Thoroughly check the connection
assembly to the brine tank:
A Check that there are no
obstructions in the connection
system.
B Check that there is a flow when the
float is in lower position.
C Check that there is no formation of
a salt bridge in the brine tank.
D Check that all components of the
brine valve operate efficiently.
Issue Cause Reset and recovery