SolarTouch
®
Solar Control System Installation and User’s Guide
SolarTouch
®
Solar Control System Installation and User’s Guide
Error Conditions
When the control panel LED indicator is solid red, a sensor error has occurred; a blinking
LED indicates an IntelliFlo
®
Pump communication problem or the IntelliFlo
®
Pump has
been manually stopped. For sensor resistance data, see page 22. If the water or solar
temperature sensor is shorted or open, heating and cooling will stop and not restart until
the condition is corrected. Note: The SolarTouch
®
Controller control panel menus can be
accessed but will not affect the error condition. If one or both of the sensors is shorted or
open and Freeze Protect is enabled, Freeze Protect will turn on.
Error Messages
Error Conditions
Using IntelliFlo and IntelliPro
®
Pumps
The displayed sensor(*) error messages are as follows:
FreezeModeDisabled FreezeModeEnabled
Water Sensor Shorted Water S Shorted Freeze Protect
Solar Sensor Shorted Solar S Shorted Freeze Protect
Both Sensors Shorted Sensors Shorted Freeze Protect
Water Sensor Open Water S Open Freeze Protect
Solar Sensor Open Solar S Open Freeze Protect
Both Sensors Open Sensors Open Freeze Protect
Note: (*) The pump will continue to operate until the problem is resolved.
Error Message Displayed Description
Pump Alarm Solar Paused IntelliFlo pump has been manually stopped.
IntelliFlo Pump COM Lost IntelliFlo pump communication cable is not properly
connected to SolarTouch Controller or no AC power
to IntelliFlo pump.
Note:BeforeworkingonanyIntelliFloorIntelliProPump(cleaningthebasket
etc.),rstturnOFFthemaincircuitbreakerandwaituntilthepump’sredalarm
LEDlightstopsblinking.
IntelliFloandIntelliProPumpsrecommendedforusewithSolarTouch
Controller
• IntelliFlo/IntelliPro 4x160 (Mfg. 2005 -2011- P/N 011013).
• IntelliFlo/IntelliPro Variable Speed (8 programmable time clocks - P/N 011018
VS 3050.
• IntelliPro Variable Speed (8 programmable time clocks,
P/N P6E6VS4H-209L).
IntelliFlo and IntelliPro Pumps notrecommendedforusewiththe
SolarTouch Control System
• IntelliFlo/IntelliPro VF 3.2 Kilowatts (P/N 011012)
• IntelliPro VS+SVRS (P/N P6E6XS4H-209L)
• IntelliFlo VS+SVRS (P/N 011017)
For more information about IntelliFlo and IntelliPro pumps, visit www.pentairpool.com.
The Displayed IntelliFlo pump error messages are as follows:
11