4
English
SC-75™ Power Center OVERVIEW
The SC-75™ salt chlorinator system comprises of a Power Center and electrolyc Cell. The Power Center is connected with the
pool circulaon pump electrical source so that the electrolyc cell only operates when the pool pump is on. It is recommended
that a pool pump mer be used to save on energy and prolong the service life of your pool pump and SC-75. A mer is not
included as part of the Power Center kit.
The Power Center enclosure can be mounted vercally on a at surface such as a wall or post no more than 3 meter (5)
away from the cell controller. The Power Center houses the transformer, fuse, and connector to the cell. 220 VAC wiring is
connected at this box, with 28 VAC output to the cell. An 8 AMP fuse is mounted on the boom of the enclosure for addional
protecon. There are no other controls or lights on the outside of the Power Center.
IMPORTANT: The power center line voltage wires must be connected to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY
located in the load/power center. This ensures that the SC-75 cell produces chlorine only when the main lter pump is on.
Transformer
SC-75 Cell
Connector
Aached incoming AC wire
to Power Center AC power
wires. (Blue and Brown)
SC-75 Power Center (model SC-75P)
(cover removed)