SC-75 Control Panel
SALT STATUS LED INDICATORS
The SC-75 salt level checks the pool water daily and displays the levels as follows:
GREEN LED: Good Salt. The pool water salt level is between 2800ppm and 4500ppm, and the SC-75 is producing chlorine.
SC-75 salt LED should always be showing GREEN level for opmum results. Ideal salt level is 3400ppm.
GREEN LED (FLASHING): Salt level is above 4500ppm. Chlorine is being produced but the salt level is too high which increases
the risk of corrosion and deterioraon of pool equipment and surfaces in and around the pool. Pool water needs to be
drained and relled 300 mm at a me unl the salt level is below 4500ppm.
RED LED: Low salt. The water salt level is below 2800ppm. The SC-75 will be producing chlorine at a reduced eciency. It
is recommended to add salt (*)
FLASHING RED LED: Very low salt. The water salt level has dropped below 2600ppm. The SC-75 will not produce chlorine
unl salt is added. The SC-75 is o. (*)
(*) Aer every salt addion, pump should run for at least 24 hours for proper diluon. Salinity readings should only be taken
aer the 24 hour diluon period.
STATUS LED INDICATORS
CELL: SHOWS THE STATUS OF THE SC-75
GREEN FLASHING: The SC-75 needs to be inspected. The blades may be calcied. The SC-75 will not be producing chlorine.
GREEN: SC-75 is performing good and producing chlorine
NO LIGHT: The SC-75 is o and not producing chlorine. It may be in an o cycle of the sanizing process and will return on
in due course.
RED: The SC-75 is in “Standby” mode (system o, no chlorine generaon) due to cold weather condion. The SC-75 will
resume chlorine producon once the water temperature goes above 11 ° C.
FLOW: THIS LIGHT INDICATES THE STATUS OF THE WATER FLOWING THROUGH THE SC-75
RED: Insucient water ow through the SC-75, no chlorine is being produced.
GREEN: Sucient water owing through the SC-75, chlorine is being produced.
OUTPUT LED INDICATORS
The three (3) LED indicators display as a bar graph to show in increments, the percentage of me the chlorine is produced
per hour of pump run me. In BOOST mode, these LEDs blink from boom to top.
Note: If no LEDs are lit, the output is set to 0% and the SC-75 Salt Chlorinator is not producing chlorine.
0% 0 LED lit - No chlorine produced - SC-75 Salt Chlorinator is o.
33.3% 1 LED lit - Produces chlorine 33% of each hour of pump run me.
66.6% 2 LED lit - Produces chlorine 66% of each hour of pump run me.
100% 3 LED lit - Produces chlorine 100% of each hour of pump run me.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair STA-RITE SC-75P and is the answer not in the manual?

Pentair STA-RITE SC-75P Specifications

General IconGeneral
BrandPentair
ModelSTA-RITE SC-75P
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals