Troubleshoong (Connued)
Problem Possible Cause Correcve Acon
FLOW LED is red. Pump fails to provide sucient water ow. Check for correct operaon of the pump,
i.e., loss of pump prime or clogged strainer
baskets.
Closed valves. Check and correct all valve alignments.
Dirty lter. Follow lter cleaning procedures.
Obstrucon in the Chlorinator cell. Remove cell for inspecon. Follow cleaning
procedures. See “Electrolyc Cell Cleaning”
SC-75 unit does not have
power.
Fuse in Power Center is open. Replace AC fuse, located at boom of Power
Center.
No A/C power to Power Center. Verify me clock is providing 220VAC to Power
Center when acve.
Transformer leads not wired correctly in
Power Center.
Verify transformer leads wired to AC source by
referring to wiring diagram decal on inside of
Power Center cover.
System Specicaons - 230 VAC
Circuit Protecon: Two pole 20AMP devise at the electrical panel.
Model SC-75P (Power Centre)
Input: 50Hz, 220-240 VAC, 220W, 1 Amp. Output: 28 VAC @ 5.2 Amp Max.
Water ow: 6m³/h (25GPM) - Max ow: 24m³/h (105GPM) - Max Pressure: 5Bar (75PSI)
SC-75 AC Wiring Instrucons :
- When using the SC-75 Salt Chlorinator and an IntelliFlo pump (or variable speed pump) with a Pentair IntelliPool Automaon
System, please read the IntelliPool installaon manual - Secon ‘Desinfectant Connecon - Alternave Salt Chlorinator.
- When using the SC-75 Salt Chlorinator with the ‘Pentair ControlPro Filtraon Manager’ and a Variable Speed pump, please
read the ‘Pentair ControPro Filtraon Manager’ installaon manual.