English
More and Less Output Buons
The More and Less buons control the percentage of me of each hour that the SC-75 Salt Chlorinator is producing chlorine
while the pump is on (see Sanizer Output LED indicators above). The lights act as a bar graph: the more lights that are on,
the more chlorine is produced. Flip the panel cover up to access the More, Less and Boost On/O buons. To exit Boost
mode, press and hold both the buons.
More: Increases the me the cell produces chlorine.
Less: Decreases the me the cell produces chlorine.
Boost On/O: Press and hold both the More and Less buons together to acvate Boost mode on or o. Boost mode sets the
sanizer output to run 100% for the next 24 hours of pool pump run me. If the me clock switches o the pump cycle, then
switches power back on the next day, Boost mode will connue unl 24 hours has elapsed since Boost mode was turned on
or Boost mode is canceled by the user. The Sanizer Output display will show a paern LED display to indicate Boost mode.
Self-Cleaning
The self-cleaning feature reduces scale buildup on the blades of the SC-75. The self-cleaning cycle tends to reduce the life
of the SC-75, therefore, it should be used only to the extent necessary to minimize the scale buildup on the blades. The self-
cleaning cycle can be adjusted to run every 3, 4, or 5 hours, whichever is the opmal for your parcular pool condions in
order to minimize scale buildup but maximize the life of the SC-75. It is factory set to two (2) hours for the rst 30 days of
operaon, then automacally switches to three (3) hours. To change the self-cleaning cycle, press and hold the LESS buon
for three (3) seconds. The sanizer output display will show the number of hours in a bar graph style. The number of output
LEDs lit is the number of reverse hours. Pressing More or Less buon will change this seng.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair STA-RITE SC-75P and is the answer not in the manual?

Pentair STA-RITE SC-75P Specifications

General IconGeneral
BrandPentair
ModelSTA-RITE SC-75P
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals