Use the following troubleshoong informaon to resolve possible problems with the SC-75 Salt Chlorinator.
Note: Switch power o to unit before to aempng service or repair. Always remove AC power to Power Center when plugging
or unplugging the SC-75 cell into the Power Center.
Problem Possible Cause Correcve Acon
Low or no chlorine Low Stabilizer (cyanuric acid) level in pool wa-
ter (outdoor pools only).
Add cyanuric acid in outdoor pools only to
maintain 30 - 50 PPM per pool professional’s
recommendaons. See Stabilizer Chart.
Insucient operang hours of the SC-75. Increase the SC-75 operang me per day.
Sanizer output percentage too low or at 0%. Increase sanitzer output by pressing the MORE
buon.
Recent increases in weather temperature with-
out increasing the SC-75 sanizer Output.
Increase sanitzer output by pressing the MORE
buon.
Temporary loss of chlorine due to heavy organ-
ic load, rain, leaves, ferlizer or heavy bather
load, recent party, or pets using pool.
Set “Boost” mode and allow to run for 24
hours. Re-check, If sll too low, super- chlorin-
ate by using an outside source. (Take pool water
sample to pool professional).
Low (less than 2600 ppm) salt level in pool
water, shuts o chlorine producon.
Observe Salt Display lights. See “Salt Level
Status LEDs”
High nitrate and phosphate level. Contact Pool Professional.
Metals present in pool water. Contact Pool Professional.
New pool water, or not shocked properly upon
startup.
Super Chlorinate Pool.
See “Start-up Procedure (Super Chlorinaon)”
Clogged or dirty cell. Remove cell for inspecon. Clean if necessary.
Red SALT LED is on. Pool water needs salt. No chlorine is being
produced.
Add salt to achieve 3400ppm.
Yellow SALT LED on
and green CELL LED
ashing
Salt level in pool water is low and may need
inspecng.
Check salt level, add if necessary to GOOD level.
Allow 24 hours for salt to mix in water. If CELL
light is sll ashing aer 24 hours, remove and
inspect cell and clean if necessary.
Green SALT LED is
ashing
Too much salt in pool. May cause damage to
pool equipment and surrounding surfaces.
Dilute pool water by draining some water, then
lling with fresh water
CELL LED is red. Water is below 12°C. The water temperature must be above 12°C to
produce chlorine.
CELL LED does not
come on.
Chlorine Producon set to 00%. Adjust CHLORINE PRODUCTION to desired
percentage.
Insucient water ow. Cell is plugged with
debris, pump has lost prime.
Remove obstrucon and/or clean cell.. Prime
pump if necessary.
Salt level below 2600 ppm. Add salt.
CELL LED is ashing
green.
Check salt level. Add salt if necessary to maintain 3400 ppm
minimum.
Cell has calcium build-up and requires clean-
ing.
Refer to Maintenance Procedure for acid wash/
cleaning. See “User Maintenance”
Check water chemistry and balance. NOTE
metal content should be 0 ppm.
Remove metals from water using chemical solu-
on.