9. ACCESSING THE FUNCTIONS
9.1 Accessing by help key
You can use the [HELP] key to display specific initial setting
(such as the prism constant and priority mode).
Press the [lLLU]+[ESC] key in mode A or B.
The help menu will then be displayed. Press [F1] [ ] [F2] [ ] or [F3] [ ] [F4] [ ] to
position the cursor to the desired item.
9.2 Accessing by 007
The R-300X allows you to enter a special code of 007 with the alphanumeric keys to
display specific initial setting. (such as the prism constant and priority mode).
Press the numeric keys [0] [0] [7] in mode A or B.The
screen will then change to the command input screen.
Press the numeric keys for the desired command
number in the Command No. Table.
(For example, press [5] [0] [1] for MEAS. MIN DISP.)
Press the [ENT] key to access the MEAS. MIN DISP.
SELECT
HELP
1. HELP
2. 401 TARGET CONST
3. 402 ATM CORR : AUTO
4. 501 TRACK MIN DISP : 1mm
5. 502 SHOT COUNT
H.angle
H.dst.
V.dst.
CLEAR
MODE A 15°C S 0
92° 30’ 20”
H.angle
H.dst.
V.dst.
CLEAR
MODE A 15°C S 0
92° 30’ 20”
H.angle
H.dst.
V.dst.
SELECT
MEAS MIN DISP
92° 30’ 20”
00 0
50 1
501
1. COARSE
2. FINE

Table of Contents