1204F - DEF System Supplement
4.2.6 DEF Lines
The following 3 DEF lines are required:
Suction line Tank to pump
Pressure Line - supply from pump to DEF injector
Return line return from injector back to tank
The DEF lines are electrically heated lines available in either 12 or 24V. They are supplied with the
appropriate quick fit connectors and available in various lengths.
The lines are heated by embedded heater wires to prevent solids from forming in the DEF solution in
colder temperatures below 11°C; the point at which DEF freezes. They have been designed,
optimised and validated to be used with system provided taking into consideration both the flow
requirement and current draw.
Correct operation of these lines is required to ensure adherence to emissions requirements. These
parts should, therefore, be selected from the Perkins product offering.
Figure 4.6Heated DEF Lines
A&I manual Publication TPD 1832 Production issue 3. Page 24 of 41