20 SEBU8337
Product Information Section
Product Identication Information
Table 2
Event Code Parameter State Trip Point Delay Time
E162 High Boost Pressure
-1
Warn Operator (1) On 300 kPa (43.5 psi)
60 seconds
-2
Action Alert (2) Always On
Map 5 seconds
E360
Low Engine Oil Pressure
-1
Warn Operator (1) On 200 kPa (29 psi)
60 seconds
-2
Action Alert (2) Always On
Map 2 seconds
-3
Engine Shutdown (3) Always On
Map 2 seconds
E361
High Engine Coolant Temperature
-1 Warn Operator (1) On 104 °C (2190 °F) 60 seconds
-2 Action Alert (2) Always On 105 °C (221 °F) 10 seconds
-3 Engine Shutdown (3) Always On 108 °C (226 °F) 10 seconds
E362
Engine Overs
peed
-1
Warn Operator (1) On
2000 RPM 1 second
-2
Action Alert (2) Always On
2050 RPM 0 second
-3
Engine Shutdown (3) Always On
2140 RPM 0 second
E363
High Fuel Supply Temperature
-1
Warn Operator (1) On 60 °C (140 °F)
60 seconds
-2
Action Alert (2) Always On 68 °C (154 °F)
60 seconds
E368
High Engine Intake Manifold Air Temperature
-1
Warn Operator (1) On 75 °C (167 °F)
60 seconds
-2 Action Alert (2) Always On 78 °C (172 °F) 10 seconds
Refer to Troubleshooting , “System Conguration
Parameters” for additional information for the
Programmable Monitoring System.