11 - 25
11.05.02 Tripping lever
Requirement
In needle rise position, the flattened pin of control lever 6 (see arrow) must drop easily into
the track of control cam 7 when activating lever 8 is activated.
Fig. 11 - 23
Screw out screw 1 and swing out connecting rod 2.
Loosen screws 3 and 4.
Bring the needle bar to needle rise position by turning the balance wheel.
Bring clamp 5 to rest on the right side of the housing.
Keeping this position, press control lever 6
to the bottom of the cam track and move it in
accordance with the requirement.
In this position, tighten screw 3.
Screw 4 remains loosened until the release trip is adjusted.
4
3
5
7
1
8
2
6