Adjustment
11 - 28
11.05.05 Release trip
Requirement
In needle rise position and with control lever 4 engaged, there must be a clearance of
approx. 0.3 mm between the bolt of the control lever and the base of the cam track.
Fig. 11 - 26
Bring the machine to needle rise position.
Manually activate engaging lever 1 so that pawl 2 engages.
Taking care to ensure that screw 3 is still loose, press control lever 4 down to the base
of the track of control cam 5.
Maintaining this position, lightly tighten screw 3 while bringing release trip 6 into a
resting position against engaging lever 1 and laterally against control lever 2 in the
direction of the arrow.
By lightly tapping on release trip 6 in the direction of the arrow, while simultaneously
tapping control lever 4, create a distance between the pin and the base of the cam track
which corresponds with the requirement.
In this position tighten screw 3.
6
3
2
1
5
6
0.3 mm
4
4