Adjustment
30
15.06.03 Distance between thread catcher and needle plate
Move thread catcher 1 (screws 2, two screws) parallel to the thread catcher holder inac-
cordance with the requirement.
Requirement
During its swivel movement thread catcher 1 should not pass the edge of the needle plate
(see arrow).
Fig. 15 - 25
1
2
2
1