Adjustment
38
Group
Parameter
Description
Setting range
Set value
2
206 Open thread tension on stop and roller presser
lift
ON - OFF OFF
207 Open thread tension after trimming
ON - OFF OFF
3
301 Take-up lever at t.d.c. position
1591 0 - 127 125
1593 0 - 127 2
302 Position of needle at bottom position
1591 0 - 127 17
1593 0 - 127 20
303 Thread trimmer magnet position on
1591 0 - 127 17
1593 0 - 127 20
304 Thread trimmer magnet position timing
1591 0 - 127 100
1593 0 - 127 103
305 Thread trimmer magnet position off
1591 0 - 127 120
1593 0 - 127 123
306 Reverse rotation position
1591 0 - 127 100
1593 0 - 127 103
307 Placed stitch position 0 - 127 7
308 Thread tension ventilation position
1591 0 - 127 98
1593 0 - 127 101
4
401 Holdoff time roller presser lift [s] 0.01 - 1.5 0.02
402 Start delay after lower roller presser [s] 0.01 - 1.5 0.15
403 Set roller presser lift [s] 0.01 - 0.2 0.03
404 Thread trimmer magnet timing [%] 10 - 50 35
405 Time to clean the thread monitor [s] 0.01 - 1.5 0.25
5
501 Maximum speed 100 - 3500 3500
502 Start backtack speed 100 - 1500 700