11.04.03 List of parameters
0 10 Bobbin thread monitor current level C 8 - 16 12
11 Bobbin thread monitor stitch counter C 0 - 255 32
(Start value)
1 100 Control panel contrast [%] A 90 - 110 100
101 Control panel key response signal A 0 - 1 1
0=tone off / 1=tone on
102 Start backtack stitches forwards C 0 - 9 3
103 Start backtack stitches in reverse C 0 - 9 3
105 Start backtack speed B 100 - 1500 900
106 Start backtack speed: C OFF - ON OFF
ON = pedal-controlled
OFF = set with param. "105"
107 Pedal-controlled start backtack speed: C OFF - ON OFF
ON = limited with parameter "105"
OFF = limited with parameter "607"
108 End backtack stitches in reverse C 0 - 9 3
109 End backtack stitches forwards C 0 - 9 3
110 End backtack speed B 100 - 1500 1000
111 No. of stitches from bright light barrier A 1 - 255 6
to seam end in manual sewing
113 Start with light barrier B OFF - ON ON
ON = only when light barrier is dark
OFF = also when light barrier is bright
114 After light barrier or stitch counting: C OFF - ON OFF
ON = stop
OFF = autom. end backtacks and
seam end
116 Soft starting stitches (soft start) A 0 - 10 1
117 Speed for soft starting stitches B 180 - 1200 400
148 Start backtacks A OFF - ON ON
ON = double / OFF = single
149 End backtacks A OFF - ON ON
ON = double / OFF = single
Group
Parameter
Setting
range
Set
value
User
level
Description