Maintenance and Care
64
These maintenance intervals are based on an average running time of a single
shift production shop. Shorter maintenance intervals are recommended for in-
creased running times.
12.02 Cleaning the machine
The required cleaning cycle for the machine depends on the following factors:
O Single or multi-shift operation
O Dust formation caused by the workpieces
Optimal cleaning instructions can therefore only be determined on a case-by-case basis.
Disconnect the machine from the electricity mains for all cleaning work by shut-
ting off the main switch or removing the mains plug! Risk of injury due to acci-
dental machine start-up!
The following tasks are recommended
during single shift operation to avoid
operational errors:
O Tilt machine backwards.
O Clean the hooks and hook area daily or
more often during continuous operation.
Return the machine to its
upright position using both
hands!
Danger of injury by crushing
between the edge of the
machine and the table top.
12 Maintenance and Care
12.01 Maintenance intervals
Cleaning ........................................................daily, several times if in continuous operation
Clean the hook area ......................................daily, several times if in continuous operation
Check oil level ...................................................................................... daily, before start-up
Lubricate the bevel gears .................................................................................. once as year
Clean the blower air filter ................................................................................... as required
Fig. 12 - 01