Input
61
8 880 Starting current main drive C 1 - 10 8
881 Filter parameter for position controller C 0 - 12 5
884 Proportional amplification C 1 - 50 25
of speed control (general)
885 Integral amplification C 0 - 50 35
of speed control
886 Proportional amplification C 1 - 50 30
of position controller
887 Differential amplification C 1 - 50 30
of position controller
889 Time for position control (0 = always) C 0 - 2550 200
890 Proportional amplification of C 1 - 50 25
higher ranking speed controller
for standstill brake (rest brake)
891 Proportional amplification of C 1 - 50 20
lower ranking speed controller
for standstill brake (rest brake)
9 901 Cutting release speed C 180 - 500 400
956 Current for stepping motor axis 2 B 30 - 63 56
957 Current for current reduction B 15 - 48 39
of stepping motor axis 2
958 Current red. time stepping motor axis 2 B 0 - 2500 2000
978 Current red. time stepping motor 2 C 0 - 99 0
979 Current red. time stepping motor 1 C 0 - 99 0
985 Position for thread clamp on B 0 - 127 34
986 Position for thread clamp off B 0 - 127 103
Group
Parameter
Setting
range
Set
value
User
level
Description