8:2
Changing the needle plate
Turn off the on/off switch
Removal
Raise the presser foot. Position the needle plate changer (bulb
remover) as shown and press the needle plate up on the right, then on
the left. It can now be easily removed.
Replacing
Place the needle plate against the rear edge of the cut-out then press
down at the front until you hear it snap in place. Before you start
sewing, check that the needle plate is lying flush with the bed of your
free arm.
Tip: Lower the feed dogs to make removing the needle plate easier.
Cleaning
Turn off the on/off switch
Remove the needle plate and lower the feed dogs. Clean the feed dogs
and hook area with the brush.
Clean the sewing machine after every 10 - 15 hours of operation.
Cleaning the display
Wipe the display with a soft, lint-free dry cloth. DO NOT use
aggressive cleansers or solvents!