EasyManuals Logo

Pfaff PicoDrive P40PD User Manual

Pfaff PicoDrive P40PD
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
c) Reset all values - ResetAll "3"
Attention:
All values are reset to their default values; a so-called
cold start is carried out!
All parameter values, including those marked with a " * " are
reset to their default values!
All seam data that have been programmed by the user are deleted!
Expiry of the parameter value reset - ResetAll "3":
- Switch off mains switch
- Press keys A+ and D+ simultaneously and hold pressed!
- Switch on mains switch
- Keep these two keys pressed until "1 2 3" (Fig. 9.13) appears on the display,
then release the keys.
By pressing the D+ key, the cold start = "3" is carried out straightaway!
By pressing any key, except A+, B+ and D+, the reset process is interrupted!
If RESET is executed, the display shows this reset version for approx . 1 sec! (Fig. 9.14)!
Fig. 9.14
Fig. 9.13
p4xpd-2-en
9.8 08-08-29

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pfaff PicoDrive P40PD and is the answer not in the manual?

Pfaff PicoDrive P40PD Specifications

General IconGeneral
BrandPfaff
ModelPicoDrive P40PD
CategoryControl Panel
LanguageEnglish

Related product manuals