c) Reset all values - ResetAll "3"
Attention:
All values are reset to their default values; a so-called
cold start is carried out!
All parameter values, including those marked with a " * " are
reset to their default values!
All seam data that have been programmed by the user are deleted!
Expiry of the parameter value reset - ResetAll "3":
- Switch off mains switch
- Press keys A+ and D+ simultaneously and hold pressed!
- Switch on mains switch
- Keep these two keys pressed until "1 2 3" (Fig. 9.13) appears on the display,
then release the keys.
By pressing the D+ key, the cold start = "3" is carried out straightaway!
By pressing any key, except A+, B+ and D+, the reset process is interrupted!
If RESET is executed, the display shows this reset version for approx . 1 sec! (Fig. 9.14)!
Fig. 9.14
Fig. 9.13