Adjusting
39
Fig. 1 - 31
1.07.07 Thread catcher height
Rule
When positioning the thread catcher 2 under the setting gauge 1, the thread catcher 2
should directly touch the setting gauge 1 without turning it.
Place the setting gauge 1 (Order No. 61-111 689-07) in the needle plate recess, so that it
stands above the thread catcher 2 (see magnifi cation).
The height setting is factory preset.
Any possible correction required can be carried out by placing a 0.2 mm thick
spacing washer underneath (Order No. 12-360 061-05) between part 3 and
part 4.
1
2
4
3