Adjusting
44
1.07.12 Parameter values
The following parameters has to be set diffrent to the regulare
P74 ED instruction manual.
Group
Parameter
Description
User level
Setting range
Set value
3
309 Position short trimmer on B, C 0 - 255 180
310 Functions A16
0 = no function
1 = midle guide
2 = short trimmer
B, C 0 - 2 2
312 Selection of midle guide B, C ON - OFF OFF
314 Funkctions A7
0 = no function
1 = edge trimmer
2 = thread-pulling sewing start
B, C 0 - 2
0
315 Funkctions A15
0 = no function
1 = Faclean thread-monitor
2 = Thread-pulling at sewing-start
B, C 0 - 2
0
316 Position to pull thread at seam-start B, C 0 - 255 235
317 Time to pull the thread at sewing-start B, C 10 - 1000 100
6
657 Stitch protection / knotting B, C ON - OFF ON
7
702 1 Needle position (down) B, C 0 - 255 20
703 Thread lever position up B, C 0 - 255 235
705 End trim signal1 B, C 0 - 255 210
706 Start trim signal B, C 0 - 255 100
707 Start thread tension release B, C 0 - 255 190
9 989
Thread-nipper at sewing-start
0 = Thread-nipper off
1 = Thread-nipper without foot-lift
2 = Thread-nipper with foot-lift
B, C 0 - 2
1