Operating Manual
Attachment and installation cooling units
DTS and DTI Series 6201C / 6301C
Multi-Controller (MC) 230 V
Version 1.0, May 2017

Table of Contents

Questions and Answers

  • B
    butlerjamesAug 14, 2025
    Why is my Pfannenberg DTS 6301C Accessories unit not cooling sufficiently?
    • O
      oconnelldavidAug 14, 2025
      There are several reasons why your Pfannenberg Accessories unit might not be cooling enough. It could be due to exceeded operating limits, so check the ambient temperature and internal load. Another cause might be too little coolant, in which case you should call authorized qualified personnel and check the unit for leakage. A dirty heat exchanger, a defective evaporator fan (internal) or condenser fan (external) could also be the reason; in these cases, clean the heat exchanger or call authorized qualified personnel to replace the fan. Also, check for any disruption in the air circulation inside the cabinet, the supply and outlet flow of air, and the DIP switch and cable connections.
  • M
    Matthew WoodAug 17, 2025
    What to do if condensate accumulates in my Pfannenberg DTS 6301C Accessories switch cabinet?
    • R
      rprattAug 17, 2025
      If condensate is accumulating in your Pfannenberg Accessories switch cabinet, it could be due to a few reasons. The exhaust temperature might be too low, so try closing the cabinet door. Also, the switch cabinet might not be sufficiently sealed, so correct any leaky points or seals. Finally, check the temperature setting.
  • R
    Richard GomezAug 20, 2025
    How to troubleshoot a Pfannenberg Accessories unit that doesn't cool but the evaporator fan is running?
    • K
      Kristen TorresAug 20, 2025
      If your Pfannenberg Accessories unit isn't cooling, but the evaporator fan is running, the temperature setting may be too high. Check the temperature setting.
  • J
    Jessica GarciaAug 25, 2025
    Why is condensate draining from my Pfannenberg DTS 6301C Accessories unit?
    • T
      Timothy SmithAug 25, 2025
      If condensate is draining from your Pfannenberg Accessories unit, it could be caused by a defective condensate evaporator or too much condensate accumulation. Try replacing the fuses for the condensate evaporator. Also, check if the switch cabinet is sufficiently sealed and correct any leaky points or seals.
  • J
    Jimmy WilliamsAug 27, 2025
    What to do if the condensate does not drain from my Pfannenberg Accessories unit?
    • B
      Brittany HicksAug 27, 2025
      If the condensate is not draining from your Pfannenberg Accessories unit, the condensate drain may be plugged up. Clean the condensate drain. Also, check whether the condensate drain hose is free from kinks and is installed with a downward slope.
  • M
    Melissa RosarioAug 30, 2025
    What to do if condensate accumulates in the switch cabinet of Pfannenberg Accessories?
    • O
      ovasquezAug 30, 2025
      If condensate is accumulating inside the switch cabinet with your Pfannenberg Accessories, the exhaust temperature might be too low; in this case, close the cabinet door. Another potential cause is an insufficiently sealed switch cabinet. Address this by correcting any leaky points or seals. Also, ensure that the temperature setting is correct.
  • S
    Susan ArroyoSep 3, 2025
    What to do if my Pfannenberg Accessories unit cools only periodically?
    • R
      Robert HernandezSep 3, 2025
      If your Pfannenberg Accessories unit cools only periodically, the temperature might be set incorrectly. Try setting a higher temperature. If the issue persists, call authorized qualified personnel to check the unit.
  • T
    Taylor ChenSep 6, 2025
    How to fix a Pfannenberg Accessories unit when condensate does not drain?
    • K
      kara91Sep 6, 2025
      If condensate isn't draining from your Pfannenberg Accessories, start by cleaning the condensate drain, as it may be plugged up. Also, verify that the condensate drain hose is free from kinks and installed with a downward slope.
  • B
    Brett HartSep 9, 2025
    What to do if Pfannenberg Accessories unit does not cool but evaporator fan is running?
    • L
      Lisa WellsSep 9, 2025
      If your Pfannenberg Accessories unit isn't cooling but the evaporator fan is running, check the temperature setting and adjust if it is too high.

Summary

2 Unit Description

2.6 Technical Data

Presents detailed technical specifications: refrigeration, electrical, dimensions.

3 Assembly and Initial Commissioning

3.4 Assembly

Guides physical assembly and mounting of cooling units.

3.5 Electrical Connection

Explains electrical component connection and wiring.

4 Operation

4.2 Multi-Controller Operation

How to operate the cooling unit using the Multi-Controller interface.

4.3 Carrying Out Menu Settings

Procedure for navigating and adjusting controller menu settings.

4.6 Error Messages

Lists error codes, causes, and solutions.

4.7 LCD Error Messages

Details LCD error messages and their meanings.

5 Service and Maintenance

5.4 Maintenance

General maintenance requirements and procedures.