EN 131Q528.2E LB 8.
Important: after having edited the option numbers as
described above, you must press OK on the remote control
before the cursor is moved to the left!
8.5 Reset of Repaired SSB
A very important issue towards a repaired SSB from a service
repair shop, implies the reset of the NVM on the SSB.
A repaired SSB in service should get the service Set type
“00PF0000000000” and Production code “00000000000000”.
Also the virgin bit is to be set. To set all this, you can use the
ComPair tool.
42PFL7613D/12_1 41641 04108 04175 45160 10115 00098 00001 00000
131
42PFL7613D/12_2 41641 04108 04175 45160 10114 00098 00001 00000
130
42PFL7633D/12_1 41641 04108 04175 45160 10115 00098 00001 00000
131
42PFL7633D/12_2 41641 04108 04175 45160 10114 00098 00001 00000
130
47PFL7603D/10_1 41641 04108 04175 45160 10119 00098 00001 00000
135
47PFL7603D/10_2 41641 04108 04175 45160 10143 00098 00001 00000
159
47PFL7603H/10_1 41641 04108 04171 45160 10119 00102 00001 00000
135
47PFL7603H/10_2 41641 04108 04171 45160 10143 00102 00001 00000
159