1-4-4 E9480FIS
Switch the clock output off.
060300 Switching the clock output off succeeded.
060301 Switching the clock output off failed.
Select an input video path to be switched to the
analogue output of the VIP.
060400 Selecting the input of the VIP succeeded.
060401 The user provided wrong input.
060402 The VIP was not accessible.
060405 This mode not available on SAA7118.
Get the device (revision) type information of the 1394
Physical layer IC.
070100 Getting the information from the physical layer IC succeeded.
070101 Missing PHY clock.
070102 Time-out error.
070103 1394 chip is not IEEE 1394a-2000 compliant.
Check the accessibility of the 1394 Physical layer IC by
writing to and reading from a specific address.
070300 Communicating with the physical layer IC succeeded.
070301 Missing PHY clock.
070302 Time-out error.
070303 Register write test failed.
Route a DV stream containing an audio and video
signal through the physical IC to the Domino. This will
be loopthrough to the video output of Domino.
070400 Routing the signals succeeded.
070405 Failed to initialise DENC.
Check whether a DV node can be detected by the
hardware.
070500 The node was detected OK.
070504 No node was detected.
Check the device type of the DENC in use.
080100 Communicating with the progressive scan DENC-IC succeeded.
080101 The IIC bus initialisation failed.
080102 No valid DENC detected.
Check the communication between the IIC controller of
the Domino and the DENC-IC.
080100 Communicating with the progressive scan DENC-IC succeeded.
080104 Communicating with the DENC failed.
080105 The IIC bus initialisation failed.
Generate a test image and make it present on the
DENC-IC.
080200 The generation of the test image succeeded.
080201 The IIC bus initialisation failed.
080202 Unable to initialise the DENC.
080203 The generation of the test image failed.
Switch off the generated test image.
080300 Turning off the test image succeeded.
080301 The IIC bus initialisation failed.
080302 The test image could not be turned off.
Turn on MacroVision.
081000 Turning on MacroVision succeeded.
081001 The IIC bus initialisation failed.
081002 Unable to access DENC.
Turn off MacroVision.
081000 Turning off MacroVision succeeded.
081001 The IIC bus initialisation failed.
081002 Unable to access DENC.
Check the communication between the digital board
and the recorder drive by issuing an Inquiry command
over ATAPI bus.
090000 Communicating with recorder drive succeeded.
090001 Recorder drive init fails.
090002 Recorder drive command fails.
Reset the basic engine.
090100 Resetting the Basic Engine succeeded.
090101 Recorder drive init fails.
Return the self-test results through the service port. 090200 Self test succeeded, no errors.
Get the version of the basic engine and that of the
optical unit.
090300 BE version OK.
090301 Recorder drive init fails.
090302 Recorder drive command fails.
Open the tray of the basic engine.
090400 The command executed successfully.
090401 Recorder drive init fails.
090402 Recorder drive command fails.
Close the tray of the basic engine.
090500 The command executed successfully.
090501 Recorder drive init fails.
090502 Recorder drive command fails.
Description Error No. Error Description