EasyManua.ls Logo

Philips Saeco Moltio - 5.2. Error Codes; 5.3. Saeco Service Center - Quick Start Guide

Philips Saeco Moltio
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MOLTIO 05 SERVICE MODE
13/13
ERROR
CODES
DESCRIPTION
01
The coffee grinder is blocked (grinder blades jammed or sensor not
reading properly)
03
The brewing unit is blocked in work position (microswitch not released
in up position after 3", torque error trying to move down, descent time
out exceeded)
04
The brewing unit is blocked in home position (microswitch not released
in down position after 3", torque error trying to move up, ascent time
out exceeded)
05
Water circuit / ow meter problems (water circuit blocked or no ow
meter signal)
10
Boiler temperature sensor short circuited
11
Boiler temperature sensor open circuit
14
The boiler temperature has exceeded the maximum allowed value
(165°c)
15
The boiler temperature has not increased by x°C in y sec (boiler power
supply disconnected, incorrect boiler tted must be a 1300W boiler, par-
tial power supply to boiler, cut out thermostat tripped)
19
Mains voltage trouble
5.2. Error codes
5.3. SaecoServiceCenter-QuickStartGuide
SaecoServiceCenter–QuickStartGuide
Press the icon to view the document
To open the attached document is necessary to save the service manual on your PC.
Saeco Service Center (SSC) is a tool with which you can re-program the machine and check the
diagnostic of the same.
You can download the software from the following link: http://logsave.logtronics.com/SSC2/publish.htm
In support of this tool it is essential to order the Saeco Programming Device:
Cod. 20000490 “KIT PROGRAMMER SERKIT SSC2”.
This kit includes the programmer and cables helpful.
All details related to the registration and operation are explained in the enclosed Quick start guide
(QSG).