Advanced Scanner Configuration Guide 43
Revision: 2.0 , technical changes excepted
MSI
Enable/Disable MSI
To enable or disable M SI, scan the appropriate bar code below.
Enable MSI
*Disable MSI
Set Lengths for MSI
The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and
includes check digits. Lengths for MSI can be set for any length, one or two discrete lengths, or lengths within a
specific range. See Table B-5 on page B-9 for ASCII equivalents.
One Discrete Length - Select this option to decode only those codes containing a selected length. For example,
select MSI Plessey One Discrete Length, then scan 1, 4, to decode only M SI Plessey symbols containing 14
characters. Numeric bar codes begin on page 51. To change the selection or cancel an incorrect entry, scan the
Cancel bar code on page 51.
MSI - One Discrete Length
Two Discrete Lengths - Select this option to decode only those codes containing two selected lengths. For
example, select MSI Plessey Two Discrete Lengths, then scan 0, 6, 1, 4, to decode only M SI Plessey symbols
containing 6 or 14 characters. Numeric bar codes begin on page 51. To change the selection or cancel an incorrect
entry, scan the Cancel bar code on page 51.