10 Application Examples
Safe standstill monitoring
Configuration in the PNOZmulti Configurator
} Standstill: depending on requirement
} Speed n1: greater than the maximum permitted speed.
If the "Overspeed" output (see red marking) = "0", either the maximum permitted speed has
been exceeded or the speed monitor has recognised a fault.
"Overspeed" output = "0" must lead to the shutdown of the relevant axis.