Overview
Operating Manual PNOZ ms2p HTL
1001401-EN-04
7
2 Overview
2.1 Scope
} Expansion module PNOZ ms2p HTL
} Jumper
2.2 Unit features
Using the product PNOZ ms2p HTL:
Speed monitor for connection to a base unit from the configurable control system
PNOZmulti
The product has the following features:
} Monitoring of 2 independent axes
} Connection per axis
– 1 incremental encoder
or
– 2 proximity switches
or
– 1 incremental encoder and 1 proximity switch
} Measured variables:
– Standstill
– Speed (8 values can be set)
– Direction of rotation
} Axis types, input device types and start mode can be selected in the PNOZmulti Config-
urator
} Status indicators for
– Supply voltage
– Incremental encoder
– Proximity switch
– Axis status, standstill and excess speed
– Faults on the system
} Proximity switch connection technology: Plug-in connection terminals (either cage
clamp terminal or screw terminal)
} Incremental encoder connection technology:
RJ45 female connector
} Galvanic isolation between the connections X1, X12 and X22
} Max. 4 speed monitors can be connected to the base unit