EasyManuals Logo

Pilz PNOZ s4 User Manual

Pilz PNOZ s4
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
PNOZ s4
Operating Manual PNOZ s4
21396-EN-21
| 6
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety relay provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN 60947-5-1 and EN 60204-1 and may be
used in applications with:
} E-STOP pushbuttons
} Safety gates
} Light grids and safety switches with detection of shorts across contacts
Improper use
The following is deemed improper use in particular
} Any component, technical or electrical modification to the product,
} Use of the product outside the areas described in this operating manual,
} Use of the product outside the technical details (see Technical details [ 22]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ s4 and is the answer not in the manual?

Pilz PNOZ s4 Specifications

General IconGeneral
Safety category4
Performance levele
SIL CL3
Supply voltage24V DC
Number of safety contacts3
Number of auxiliary contacts1
Stop category0 / 1
Width45 mm
Depth121 mm
Rated operational current Ie6 A
StandardsEN ISO 13849-1, EN 62061