EasyManuals Logo

Pilz PNOZ X1 User Manual

Pilz PNOZ X1
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
PNOZ X1
Operating Manual PNOZ X1
19045-EN-10
| 10
Preparing for operation
Supply voltage/input circuit AC DC
E-STOP
S1
A1
L1
A2
N
S1
A1
L+
A2
L-
Safety gate
N
Start circuit Automatic start Manual start
E-STOP/safety gate
Y1
Y2
S3
NOTICE
In the event of an automatic start or manual start with bridged start
contact (fault):
The unit starts up automatically when the safeguard is reset, e.g. when the
E-STOP pushbutton is released. Use external circuit measures to prevent
an unexpected restart.
Feedback loop Automatic start Manual start
Contacts from external contactors
K5
K6
K5
L1
K6
Y1
Y2
S3
N
13 (23, 33)
14 (24 ,34)
Legend
} S1: E-STOP pushbuttons
} S3: Start button

Other manuals for Pilz PNOZ X1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ X1 and is the answer not in the manual?

Pilz PNOZ X1 Specifications

General IconGeneral
TypeSafety Relay
Supply Voltage24 VDC
Auxiliary Contacts1 N/C
Width45 mm
MountingDIN Rail
Number of safety contacts2
Stop Category0
Height87 mm
Depth121 mm
Rated current6 A
Protection classIP20
Safety Contacts2 N/O
Operating Temperature Range-10°C to +55°C
Weight200 g