EasyManuals Logo

Pilz PNOZ X3 User Manual

Pilz PNOZ X3
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
PNOZ X3
Operating Manual PNOZ X3
20547-EN-10
28
Relay outputs 774318 774319
Utilisation category of safety con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 2000 VA 2000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 200 W 200 W
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 2000 VA 2000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 200 W 200 W
Utilisation category
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Utilisation category of safety con-
tacts
AC15 at 230 V 230 V
Max. current 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 6 A 6 A
Utilisation category of auxiliary con-
tacts
AC15 at 230 V 230 V
Max. current 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 6 A 6 A
Utilisation category in accordance
with UL
Voltage 240 V AC G. P. 240 V AC G. P.
With current 8 A 8 A
Voltage 24 V DC Resistive 24 V DC Resistive
With current 5 A 5 A
Pilot Duty B300, R300 B300, R300

Other manuals for Pilz PNOZ X3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZ X3 and is the answer not in the manual?

Pilz PNOZ X3 Specifications

General IconGeneral
Supply Voltage24 V DC
Contacts3 N/O, 1 N/C
Width45 mm
Depth121 mm
Safety Category4
Performance Levele
SILCL3
Rated Current6 A
Contact MaterialAgSnO2
Protection ClassIP20
Weight200 g
Stop Category0
Operating Temperature Range-10°C to 55°C

Related product manuals