PNOZ X8P
Operating Manual PNOZ X8P
19820-EN-10
| 10
Function Description
The safety relay PNOZ X8P provides a safety-oriented interruption of a safety circuit. When
supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the
feedback loop Y1-Y2 and the start circuit S33-S34 are closed. The "START" LED is lit.
} Input circuit is closed (e.g. E-STOP pushbutton not operated):
LEDs "CH1 IN" and "CH2 IN" will light.
The "START" LED goes out.
Safety contacts 13-14, 23-24 and 33-34 are closed, auxiliary contacts 41-42 and
51-52 are opened. The unit is active.
LEDs "CH1" and "CH2" will light.
A high signal is present at the semiconductor output switch state Y32.
} Input circuit is opened (e.g. E-STOP pushbutton operated):
LEDs "CH1 IN" and "CH2 IN" go out.
Safety contacts 13-14, 23-24 and 33-34 are opened redundantly, auxiliary contacts
41-42 and 51-52 are closed.
The LEDs "CH1" and "CH2" go out.
A low signal is present at the semiconductor output switch state Y32.
Semiconductor output supply voltage Y35
} A high signal is present at semi-conductor output Y35 if the supply voltage is present and
the internal fuse has not blown.
Operating modes
} Single-channel operation: No redundancy in the input circuit, earth faults in the start and
input circuit are detected.
} Dual-channel operation with detection of shorts across contacts: Redundant input circuit,
PNOZ X8P detects
earth faults in the start and input circuit,
short circuits in the input circuit,
shorts across contacts in the input circuit.
} Dual-channel operation without detection of shorts across contacts: Redundant input cir-
cuit, detects PNOZ X8P
earth faults in the start and input circuit,
short circuits in the input circuit.
} Automatic start: Unit is active once the input circuit has been closed.
} Manual start: Unit is active once the input circuit and the start circuit are closed.
} Monitored start: Unit is active once
the input circuit is closed and then the start circuit is closed and opened again.
the start circuit is closed and then opened again once the input circuit is closed.
} Increase in the number of available contacts by connecting contact expandsion modules
or external contactors/relays.