PSEN opII3H Series
Operating Manual PSEN opII3H Series
1003503-EN-05
| 41
Meaning
Red
Red
Green
Undervoltage; OSSD in the OFF
state
1. Ensure that the supply voltage
corresponds to the information
in the Technical
details [ 48].
2. Restart [ 42] the safety
light curtain.
Indicators on the transmitter
Meaning
green red green green
Safety light curtain is started
green green
Safety light curtain in operation
Transmitter sends uncoded
green
green
green
Safety light curtain in operation
Transmitter sends A-coded
green
green
green
Safety light curtain in operation
Transmitter sends B-coded
red red
An error has occurred.
Perform a safety light curtain
restart [ 42].
red
red
green
Overtemperature; OSSD in the OFF
state
1. Ensure that the ambient temperature
corresponds to the information in the
Technical details [ 48].
2. Perform a safety light curtain
restart [ 42].
red
red
green
Undervoltage; OSSD in the OFF state
1. Ensure that the supply voltage cor-
responds to the information in the
Technical details [ 48].
2. Perform a safety light curtain
restart [ 42].