Technical specs
Powered by 13.8VDC, nominal
Operating Voltage Range: +9 to +14 VDC
Current consumption:
Min.: 50mA (max.)
Illuminating: 90mA
Quick guide
LED
Type
Status
Indicates
Red
Arming
Steady On
System armed Away/all partitions armed
Off
System disarmed/all partitions disarmed
Flashes once
every second
Exit delay in progress (in all or some partitions)
Flashes once
every two seconds
One or more partitions are armed (where relevant)
Green
Ready
To
Arm
Steady On
System can be armed
Off
One or more zones are open or a fault exist
Orange
Fault
Flashes once
every 0.5 second
One or more faults exist, system/partition is disarmed.
Off
No fault exist (or the system is armed)
Blue
Mains
Steady On
AC OK
Off
AC loss