Chap. 6: Zones
29
Parameter
Description
Partition Allocation
Select the zone’s partitions. The selected numbers will stay on and
not flash.
Soak Test Mode
Select to put the zone in test mode for up to one week. See Chap. 10,
on page 39 for details.
6.2 Zone Types Settings
System Configuration
Zones
Zone Types Settings
Zone Type
Attributes
Burglary, Panic,
Silent Panic, Fire,
Duress, Medical,
Anti-Mask, Shock
Sensor, Key Switch
Modes, Custom Zone
Types
1) Sensitivity: set the zone sensitivity in milliseconds. Range:
1-3000, default: 800.
Sensitivity is the time period between opening the zone (relay),
and triggering the alarm. Closing the relay for one second resets
the zone.
2) Attributes: see below.
3) Audible Notification: select from the list:
Alarm tone: when calling the contacts, hi-lo alarm will be
sounded.
Key Switch Types
Key Switch in Away/Home 1-4: select the key type and set its
sensitivity (see above).
Custom Zone Types
4) Custom Zone Type 1-5: see the other zone types above, and in
addition:
1) Trigger & Report: select a standard zone type (Burglary,
Panic, Etc.) to be used for reporting the CMS and triggering
outputs, or
Custom Type
. If you select
Custom Type
you
can use it to trigger outputs to activate/deactivate special
devices such as pumps and heaters).
2) Name: user text, up to 16 characters.
6.2.1 Attributes
System Configuration
Zones
Zone Types Settings
Attributes
The zone type attributes are listed in the table below:
Attribute
When selected...
Trigger Sirens
The
External
and
Internal Siren
programmed output types will be
triggered in alarm, and activate the sirens (by default. See Section 7.1, on
page 31 for a warning).
Ext. Siren at
Disarm
The
External
Siren
programmed output type will be triggered in alarm,
and activate the external siren, even while the FORCE is at disarm.
Reports at
Disarm
Reports to the CMS will be sent, even while the FORCE is at disarm.
Auto-bypass
If this zone triggers the alarm 3 times while the system is armed, the
zone is automatically bypassed (a
Zone Bypass
report is generated) until
the system/partition is disarmed, or until the
Auto-bypass Limit
time
elapses. See Chap. 10, on page 39.
Different Siren
Tone
A different tone will be sounded when this zone triggers the alarm

Table of Contents

Other manuals for Pima FORCE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pima FORCE and is the answer not in the manual?

Pima FORCE Specifications

General IconGeneral
BrandPima
ModelFORCE
CategorySecurity System
LanguageEnglish

Related product manuals