PDP-436SXE
84
1234
1234
C
D
F
A
B
E
6.4 LIST OF RS-232C COMMANDS
RS-232C commands can be used in Service Factory mode. Before using RS-232C commands, it is necessary to change the factory
presetting.
See "6.2 USING RS-232C COMMANDS".
[Note ; If you want to see version infomation (ex. QS1, QS6, Factory, Menu), Please see 10 seconds after starting.]
1. RS-232C command for Main microcomputer
Command Operation Remarks
B
BSL Adjust side mask B
C
CNG Clearing Main NG information
CHR Clearing Hour meter
D
DW∗ Decreasing the adjustment value by* ∗:1-9, 0(0 means 10),F(making the adjustment value the minimum)
F
FAN Turning Service Factory mode off.
FAY Turning Service Factory mode on.
FST Final Set Up
G
GSL Adjusting side mask G
I
INA Selection of tuner for terrestrial analog signals.
INC∗∗∗ Selection of tuner for terrestrial digital signals
INPS01 Input selection: input 1
INPS02 Input selection: input 2
INPS03 Input selection: input 3
INPS04 Input selection: input 4
O
OSDS00 Turning the On-Screen Display off
Permit On-Screen Display.
OSDS01 Turning the On-Screen Display on
Prohibit On-Screen Display.
436SXE model only ∗ : channel number
P
POF Turning the power off.
PON Turning the power on.
Q
QS1 Obtaining the version data for each device.
QS6 Obtaining the any version.
QMT Obtaining the MR temperature information.
QNG Obtaining NG data of the MR.
R
RSL Adjustment od side mask R
U
UP∗ Increasing the adjustment value by * ∗:1-9, 0(0 means 10),F(making the adjustment value the maximum)
Z
ZME Initializing of the EEPROM video data